Mains sockets in bathrooms.

#1 Post by L Austin France »

I'm just about to replace a wall mounted fan heater in a bathroom but would like one thing clarified.
The existing heater is wired through a dedicated circuit & hard wired via a fixed outlet just below it. The heater is mounted below a window with bottom horizontal outlet.
The new IP23 heater comes pre-wired with a plug which I'm reluctant to cut off & probably invalidate any guarantee. This heater comes with feet if floor standing is required but also with a template & instructions for wall mounting.
The heater is well away from both bath/shower & basin so complies in this respect so presumably OK to swop fixed outlet for socket.
Can anyone confirm this?

User avatar
Blaze
Posts: 5673
Joined: Mon Jul 12, 2021 9:06 pm
Location: Ille et Villaine (35)

Mains sockets in bathrooms.

#2 Post by Blaze »

Electrical rules and bathrooms can be complicated - we found we couldn't do everything we wanted to do when recently renovating an old house to accommodate beach lifeguards in Saint Malo

You need to look at the norms for bathrooms NF C 15-100 to be sure of doing the right thing.
https://izi-by-edf.fr/blog/nfc-15-100-salle-de-bain

That said, we did exactly what you want to do when we renovated our bathroom : took down the wired in heater and put in a socket for a plug in convector heater, well away from basins and enclosed shower. The complications come if you have an open "wet-room" with an unenclosed shower/drainage.

User avatar
RobertArthur
Posts: 3048
Joined: Sat Jul 17, 2021 3:10 pm
Location: Nièvre

Mains sockets in bathrooms.

#3 Post by RobertArthur »

Les zones de sécurité and sockets.

Wall mounted heaters: always a circuit specialisé and a sortie de câble.

Anything else? Yes, acccording to Amendment A5 (27-11-2015) of the French NFC 15-100 regs all circuits in your house —including those for fixed electric radiators — must be protected by a 30 mA residual current device. Something to check in your tableau électrique if the electrical installation dates from before 2015. Perhaps more work than only a new socket.

Other bathroom questions? Many answers.

L Austin France
Posts: 2245
Joined: Sat Sep 04, 2021 1:47 pm
Location: sw 29

Mains sockets in bathrooms.

#4 Post by L Austin France »

Many thanks to you both for replies.